PREFERENCE 7.8.0 PHOENIX 7.8.0 PTF Number: S780005 DATE: 06/05/2002 Applicability: PHOENIX and PREFERENCE Problem: If the CBRCIC program is included in the CICS Shutdown PLT, then the following error message may be encountered when the CICS region is shutdown: @## DFH4200A jobname CEMT Circumvention: Do not include the CBRCIC program in the CICS Shutdown PLT. Action: Apply the following PTF. //S780005 JOB //FIX EXEC PGM=AMASPZAP, // PARM=IGNIDRFULL //SYSLIB DD DSN=GSP.LINKLIB,DISP=SHR //SYSPRINT DD SYSOUT=X //SYSIN DD * * NAME CBRCIC FIXAPPL * VER 06 00 * REP 06 05 * * NAME CBRCIC CBRCIC * VER 01E4 4110,D068 VER 0A80 0000,0000,0000,0000 VER 0A88 0000,0000,0000,0000 VER 0A90 0000 * REP 01E4 47F0,3A80 REP 0A80 D503,B010,3A4E,4780 REP 0A88 3258,4110,D068,47F0 REP 0A90 31E8 * CHECKSUM 3A266D4A /* //