PHOENIX 7.9.1 PREFERENCE 7.9.1 PTF Number: S791008 DATE: 10/19/2007 Applicability: All PHOENIX and PREFERENCE Clients using our CICS Interface. Problem: With the release of z/OS 1.9 the PCCA control block can optionally be moved about the 16 Meg line. If you have the PCCA control block moved above the 16 Meg line, this zap must be applied for PHOENIX/PREFERENCE to be compatible with this change. Prerequisites: None. Coreq: Apply this PTF and PTF S791007. Action: Apply the following PTF. //S791008 JOB //FIX EXEC PGM=AMASPZAP, // PARM=IGNIDRFULL //SYSLIB DD DSN=GSP.LINKLIB,DISP=SHR //SYSPRINT DD SYSOUT=X //SYSIN DD * * NAME CBRCIH CBRCIH * VER 01DA D200,600D,B01A VER 0210 D203,D210,6010 VER 0C08 0000,0000,0000,0000 VER 0C10 0000,0000,0000,0000 VER 0C18 0000,0000,0000,0000 VER 0C20 0000,0000,0000,0000 VER 0C28 0000,0000,0000,0000 VER 0C30 0000,0000,0000,0000 VER 0C38 0000,0000,0000,0000 VER 0C40 0000 * REP 01DA 47F0,3C08,0000 REP 0210 47F0,3C22,0000 REP 0C08 D200,600D,B01A,4133 REP 0C10 0000,41E0,31E0,56E0 REP 0C18 3C1E,1F77,0B7E,8000 REP 0C20 0000,4133,0000,41E0 REP 0C28 3C34,54E0,3C3E,16E7 REP 0C30 1F77,0B7E,D203,D210 REP 0C38 6010,47F0,3216,7FFF REP 0C40 FFFF * CHECKSUM F4BE2927 * /* //